Local Exhaust Ventilation Testing & LEV Inspections

Local exhaust ventilation testing and LEV inspections

Expert LEV testing and inspection solutions.

WTS is a leading independent UK water, air and environmental services company offering a range of professional Local Exhaust Ventilation testing, LEV inspections and environmental health and safety solutions to organisations throughout the UK.

Our Local Exhaust Ventilation testing and LEV inspection services are delivered by fully trained, in-field LEV experts who combine the latest high performance testing and analysis equipment and laboratory analysis techniques to help reduce exposure to harmful dust, mist, fumes, gas and other airborne contaminants in the workplace environment.

Expert Local Exhaust Ventilation Testing & LEV Inspections

Our expert LEV testing, inspection and monitoring solutions include:

  • Regulatory compliance

    Local Exhaust Ventilation testing and inspection services to meet the Control of Substances Hazardous to Health Regulations (COSHH) 2002 and the Health & Safety Executives HSG258 standards.

  • Local Exhaust Ventilation testing

    Detailed LEV testing, measurement and examination of the technical performance of the ventilation system.

  • LEV risk assessments

    Detailed risk assessments involving a thorough visual examination to verify the LEV system is in efficient working order, in good repair and in a clean condition.

  • Control of worker exposure

    Detailed assessment to check the LEV system’s ability to adequately control worker exposure to harmful dust, fumes and other airborne contaminants.

Full National UK Coverage

With offices in London serving the South and South East England, Manchester (North West), Birmingham (Midlands), Bristol (South East England and Wales), Leeds (North and North East) and Glasgow (Scotland), supported by regional teams of specially trained engineers, in-field LEV specialists and technical experts we can offer exhaust ventilation testing and assessment solutions throughout the UK.

Contact WTS today to learn how our expert air safety solutions can help safeguard your business and protect the safety and health of your employees. To speak with one of our Local Exhaust Ventilation experts call us on 0330 223 31 31 or simply use the button below to get our full contact details or submit our contact form.

The Dangers of Airborne Contaminants in the Workplace

Every year thousands of people across the UK die as a result of breathing in harmful dust and fumes at work.

Common conditions include asthma, lung scarring and cancer.

A common way businesses can reduce these risks is to control such airborne contaminants by using a properly designed, maintained and operated local exhaust ventilation system.

What is Local Exhaust Ventilation?

Local Exhaust Ventilation or LEV describes a special mechanical ventilation system used in the workplace that is designed to carefully remove harmful dust, mist, fumes, gas and other airborne contaminants from the air to reduce exposure and protect the health and safety of workers.

What is the Law covering LEV?

In the UK it is the employers’ responsibility to ensure that employee exposure to airborne contaminants in the workplace is reduced to levels as low as is reasonably practicable.

The employers’ legal responsibilities are dealt with under the Health and Safety at Work etc. Act 1974, the Control of Substances Hazardous to Health Regulations (COSHH) 2002 (as amended) and the Management of Health and Safety at Work Regulations 1999 (MHSWR).

The Health & Safety Executive also publish a comprehensive guidance document HSG258 “Controlling airborne contaminants at work, A guide to local exhaust ventilation (LEV)”.

HSG258 provides guidance for employers and their employees, LEV designers, installers and examiners and describes the principles and good practice of selecting, designing, commissioning and testing LEV systems.

Download a full copy of the latest HSG258 here… HSG258 →

How often do I need Local Exhaust Ventilation Testing?

Under the COSHH Regulations employers who use Local Exhaust Ventilation systems to control hazardous substances, must ensure that the system is operating effectively.

To do this the employer should carry out regular and detailed inspections and testing of the system.

The maximum time between tests of most LEV systems is 14 months although some higher risk systems will require more frequent testing.

However, if wear and tear has reduced the effectiveness of the system then the test and inspection frequency should be increased.

It is also a recommendation of the HSE that regular reviews of the systems of work be carried out.

What does LEV Testing & Inspection involve?

Our LEV examination and testing procedures are performed by suitably competent assessors using the latest high performance analysis equipment including Pitot tubes, smoke generators, dust lamps, anemometers and air sampling equipment.

We also offer a comprehensive range of laboratory testing and analysis services to support our specialist in-field operations.

Our detailed LEV testing assessments follow the requirements identified by the HSE in HSG258 and comprise three distinct stages as follows:

  • Stage 1

    An initial risk assessment involving a thorough visual examination to verify the LEV is in efficient working order, in good repair and in a clean condition.

  • Stage 2

    Measurement and examination the technical performance of the extract ventilation system. This data is then compared against the original commissioning and other sources of relevant data to determine any performance issues.

  • Stage 3

    A detailed assessment of the ventilation system to check its ability to adequately control worker exposure to airborne pollutants.

Expert Local Exhaust Ventilation Testing & LEV Inspection Solutions

Contact WTS today to find out more about our expert Local Exhaust Ventilation testing and LEV inspection solutions and how we can help improve workplace health, safety and compliance issues.

With offices in London serving the South and South East England, Manchester (North West), Birmingham (Midlands), Bristol (South East England and Wales), Leeds (North and North East) and Glasgow (Scotland), supported by regional teams of specially trained engineers, in-field LEV specialists and technical experts we can offer professional, cost effective Local Exhaust Ventilation testing and inspection support solutions across the whole of the UK.

Contact us today for more information or for your FREE, no obligation quote.

You may also be interested in…

Air pollution in London air quality improvement
Legionnaires’ disease: A Health & Safety Perspective from 1991
What is Antibiotic Resistance?
Legionella Testing, Water Sampling of Spas & Fountains during Legionnaires' Disease Outbreaks
How to Sample Cooling Towers for Legionella Bacteria
Improving Dust Extraction & Control in Woodworking Environments
Sampling Potable Water for Legionella Bacteria: Legionnaires Disease Outbreaks
Legionella Testing and Water Sampling: Legionnaires Outbreak Investigations

Further reading…

HSG258 – Controlling airborne contaminants at work, A guide to local exhaust ventilation testing and more… HSG258 →

Clearing the air. A simple guide to buying and using local exhaust ventilation systems… clearing the air →

Working with substances hazardous to health: A brief guide to COSHH… A brief guide to COSHH →

Institute of Local Exhaust Ventilation Engineers (ILEVE)… ILEVE website →

Summary
LEV Testing and Local Exhaust Ventilation Inspections
User Rating
5 based on 620 votes
Service Type
LEV Testing and Local Exhaust Ventilation Inspections
Provider Name
Water Treatment Services,
Area
United Kingdom & Ireland
Description
Expert Local Exhaust Ventilation testing & LEV inspections to meet COSHH & HSE HSG258 standards. More on our Local Exhaust Ventilation & LEV testing here. Our Local Exhaust Ventilation testing and LEV inspection services combine the latest high performance testing and analysis equipment to reduce exposure to harmful dust, mist, fumes, gas and other airborne contaminants.